Electrical installation
Connection data
l
48
EDK94ZMR47XDB DE/EN/FR/ES/IT 4.0
6.3
Connection data
Mains
Terminal X320
Labelling
Description
L1
L2
L3
Connection of the L1, L2, L3 mains phases
+
Connection for the supply−side PE conductor with M5 ring cable lug
SSP94NF406
Terminal data
Max. conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
E94AZMR0264xDB
10
6
1.2 ... 1.5
10.6 ... 13.3
1.0 x 4.0
E94AZMR0474xDB
25
2
2.5
22.1
1.0 x 6.5
PE connection data
Æ
Starting torque
!
[mm]
[Nm]
[lb−in]
E94AZMR0264xDB
M5
3
26.5
PH2
E94AZMR0474xDB
24 V supply
Terminal X323
Labelling
Description
GE
GND external supply
SSP9400X11
24E
24 V external supply through safely separated power supply unit
(SELV/PELV)
IEC 61131−2, 22.8 ... 28.8 V, residual ripple max. ±5 %
Current during operation: 450 mA
Starting current: max. 4 A for 100 ms
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.2 ... 2.5
24 ... 12
Spring terminal
With wire end
ferrule
Stripping length / contact length: 10 mm