26

EDK94PNE36 DE/EN/FR/ES/IT 3.1

Overview

Standard device

0

Pos.

Description

X11

24 V supply

X12

4 digital outputs

1 digital input

2

Nameplate, retractable

3

Setting of mains voltage/brake chopper threshold

4

Upper cap

The LED display enables fast indication of several operating states.

LED

Labelling

Colour

Description

OVERHEAT

Red

Overtemperature

MAINS

Green

Mains voltage OK

BRCHOP FAIL

Red

Short circuit on brake chopper

24 V

Green

24 V supply voltage OK

SSP94LED21

BRCHOP ON

Yellow

Brake chopper active

Pos.

Symbol

Description

5

{

Long discharge time: All power terminals carry hazardous voltages for at
least 3 minutes after mains disconnection!

}

High discharge current: Fixed installation and PE connection to EN 61800−5−1
required!

'

Electrostatic sensitive devices: Before working on the device, personnel must
ensure that they are free of electrostatic charge!

Installation backplane

1

Pos.

Description

X111

Mains (supply from above, e.g. from top filters)

DC−bus voltage (compatible with 9300 series)

X112

Mains (supply from below, e.g. from built−on filter)

External brake resistor

X109

DC−bus busbar +

Direct connection of

9400 axis modules,

device sizes 1 ... 3

X110

DC busbar −

6

EMC shield clamp

© 2009 Lenze Automation GmbH, Hans−Lenze−Str. 1, D−31855 Aerzen
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Automa-
tion GmbH.
All information given in this documentation has been selected carefully and complies with the hardware and software described.
Nevertheless, discrepancies cannot be ruled out. We do not take any responsibility or liability for any damage that may occur. Ne-
cessary corrections will be included in subsequent editions.