Safety instructions

Residual hazards

2

l

33

EDK94PNE36 DE/EN/FR/ES/IT 3.1

2.2

Residual hazards

Protection of persons

ƒ

Before working on the power supply module, check that all power terminals are
deenergised

– because the power terminals L1, L2, L3, +UG, −UG, Rb1, Rb2, X109 and X110 carry

hazardous voltages for at least 3 minutes after mains disconnection.

– because the power terminals carry hazardous voltages even when only the mains

voltage is applied.

Device protection

ƒ

Connect/disconnect all pluggable terminals only in deenergised condition!

ƒ

Detach the power supply modules from their installation backplanes only in
deenergised condition!

ƒ

The unit only functions properly when the 24 V supply is switched on!