2 electrical data, Electrical data, Technical data – Lenze E94APNE User Manual

Page 38: Input data, Output data

Advertising
background image

Technical data

Electrical data

3

l

38

EDK94PNE36 DE/EN/FR/ES/IT 3.1

3.2

Electrical data

Basis of the data

Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

230

180 − 0 % ... 264 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

500

400 − 0 % ... 550 + 0 %

45 − 0 % ... 65 + 0 %

Input data

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C



max. +55 °C



E94APNE0104

230/400/500

50/60

8/8/8

6/6/6

3

E94APNE0364

230/400/500

50/60

29/29/29

21.8/21.8/21.8

3

 Temperature in the control cabinet

Voltage

Continuous input power

Type

[V]

S

L

[kVA]

E94APNE0104

230/400/500

3.2/5.5/6.9

E94APNE0364

230/400/500

11.5/20.1/25.1

Output data

Voltage

Frequency

1)

Current [A]

Number of

phases

Type

[V]

[Hz]

max. +45 °C



max. +55 °C



E94APNE0104

325/565/705

0 (DC)

10/10/10

7.5/7.5/7.5

2

E94APNE0364

325/565/705

0 (DC)

36/36/36

27/27/27

2

 Temperature in the control cabinet

Voltage

Output power X109, X110, +UG, −UG

Type

[V]

With mains filter P

aDC

[kW]

Without mains filter P

aDC

[kW]

E94APNE0104

325/565/705

2.8/4.8/6.0

2.1/3.6/4.5

E94APNE0364

325/565/705

10.1/17.5/21.8

7.5/13.0/16.2

Power loss P

V

[W]

Type

Total (when operating with I

aN

)

Constant (control electronics only)

E94APNE0104

55

5

E94APNE0364

110

5

Advertising