Wiring of the standard device 7, 24 v supply, Stripping length / contact length: 10 mm – Lenze E94APNE User Manual
Page 45
![background image](/manuals/565768/45/background.png)
Wiring of the standard device
l
45
EDK94PNE36 DE/EN/FR/ES/IT 3.1
24 V supply
Terminal X11
Labelling
Description
GE
GND external supply
SSP9400X11
24E
24 V external supply through safely separated power supply unit
(SELV/PELV)
IEC 61131−2, 19.2 ... 28.8 V, residual ripple max. ±5 %
Current during operation: 450 mA
Starting current: 4 A for 100 ms
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.2 ... 2.5
24 ... 12
Spring terminal
With wire end
ferrule
Stripping length / contact length: 10 mm
Digital inputs, digital outputs
Terminal X12
Labelling
Description
GOI
GND digital out/in
DI1
External control of the brake chopper for discharge after power−off
(24−V supply at X11 required)
DO1
Mains OK
DO2
Brake chopper active
DO3
Short circuit in brake chopper
SSP9400X12
DO4
Heatsink overtemperature
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.2 ... 2.5
24 ... 12
Spring terminal
With wire end
ferrule
Stripping length / contact length: 10 mm