5

Mechanical installation

Important notes

EDK94AZMS DE/EN/FR/ES/IT 8.0

42

l

H1_MechINS−Fi NbMontage_GG2−3_EN

5

Mechanical installation

Important notes

ƒ The mounting location must always comply with the operating conditions specified

in the technical data (

^ 38). Take additional measures if necessary.

ƒ The mounting plate of the control cabinet must have the following properties:

– electrically conductive
– free of lacquer

ƒ The mechanical connections must always be ensured.
ƒ A free air circulation must be ensured for dissipating the heat.

)

Note!

The filter can be mounted in two different variants. This results in differing
mounting dimensions.

ƒ

Standard mounting
– The filter is mounted below the mounting base of the basic device. The

grid hole pattern of the L−force 9400 device series can be used.

ƒ

Side−by−side mounting for small control cabinet depth
– Device size I: The filter is mounted left to the basic device. The grid hole

pattern of the L−force 9400 device series can be used.

– Device sizes II and III: The filter is turned by 90° and mounted left to the

basic device. The grid hole pattern of the L−force 9400 device series
cannot be used.

)

Note!

For standard mounting and side−by−side mounting of size I devices, observe
that the effective thread length of the two integrated lower fastening screws
is 5 mm. The fastening thread therefore must start directly at the contact
surface to ensure a friction−locked connection and full−surface contact of the
filter.

For side−by−side mounting of size II and III devices, these screws are not used.