Side-by-side mounting - device size i, Mounting steps, Side−by−side mounting − device size i – Lenze E94AZMS0314 User Manual

Page 46

Advertising
background image

5

Mechanical installation

Side−by−side mounting − device size I

EDK94AZMS DE/EN/FR/ES/IT 8.0

46

l

H1_MechINS−Fi NbMontage_GG2−3_EN

Screws

Tightening torque

E94AZxS0044

2 x M5x20

3.4 Nm (30 lb−in)

E94AZxS0104

E94AZxS0294

2 x M5x25

3. Under limited space conditions, filter and mounting base can be connected

electrically. (

^ 49)

4. Screw the filter onto the mounting plate.

– Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
– If further devices are to be mounted directly adjacent on the right−hand side of the

filter, do not tighten the screws fully before all devices are mounted and aligned.

– Tightening torque: 3.4 Nm (30 lb−in).

I

Tip!

Under limited space conditions, filter and mounting base can be connected
electrically when step 2 has been carried out.

Side−by−side mounting − device size I

Mounting steps

How to proceed for side−by−side mounting:
1. Prepare M5 threaded holes on the mounting plate, for instance according to the

mounting grid.
– Always use all mounting points specified.

2. Mount the filter on the prepared mounting plate to the left of the mounting base.

– Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
– If further devices are to be mounted directly adjacent on the right−hand side of the

filter, do not tighten the screws fully before all devices are mounted and aligned.

– Tightening torque: 3.4 Nm (30 lb−in).

Advertising
This manual is related to the following products: