Technical data – Lenze E94AZRS0294 User Manual

Page 41

Advertising
background image

Technical data

General data and operating conditions

4

EDK94AZRS DE/EN/FR/ES/IT 6.0

41

l

H1_Daten−Abmess E94AZRS GG 1−3_en

Environmental conditions

Climate

Storage

IEC/EN 60721−3−1

1K3 (−25 ... +60 °C)

Transport

IEC/EN 60721−3−2

2K3 (−25 ... +70 °C)

Operation

IEC/EN 60721−3−3

3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C:
Device size 1 ... 7: 2.5 %/°C
Device size 8S ... 10: 1 %/°C

Site altitude

0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m

Pollution

EN 61800−5−1

Degree of pollution 2

Vibration resistance

(9.81 m/s

2

= 1 g)

Transport

IEC/EN 60721−3−2

2M2

EN 61800−2

2 ... 9 Hz: amplitude 3.5 mm

10 ... 200 Hz: acceleration resistant up to 10 m/s

2

200 ... 500 Hz: acceleration resistant up to 15 m/s

2

Operation

Germanischer
Lloyd

5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g

IEC/EN 60068−2−6

10 ... 57 Hz: amplitude 0.075 mm

57 ... 150 Hz: acceleration resistant up to 1 g

Mounting conditions

Mounting place

In the control cabinet

Mounting position

Vertically

Free space

The required free space results from the mounting
position and the specifications of the standard device.

Mounting position

Standard

Footprint mounting; standard device is screwed on
the filter

Variant

Side−by−side mounting; filter is directly screwed to the
left of the standard device (

^

Mechanical

installation)

Advertising
This manual is related to the following products: