Electrical installation

Mounting steps

6

EDK94AZRS DE/EN/FR/ES/IT 6.0

53

l

H1_E_INST−Fi Verdraht

Standard device

Cable X302

Labelling

Description

1
2
3

Filter output conductor (lead with wire end ferrule, colour
BK)

PE

Output−side PE conductor (lead with M5 fork−type cable
lug, colour GN/YE)

SSP94FF007

Mounting steps

Proceed as follows to connect the filter:
1. Connect the filter output cable (X302) to terminal X100 of the standard device.
2. Connect the mains cable to terminal X301.
3. Attach the supply−side PE conductor to the PE conductor screw using a ring or

fork−type cable lug.
– The PE connection must comply with EN 61800−5−1.