Mechanical installation

Standard mounting

EDK94AZRS DE/EN/FR/ES/IT 6.0

46

l

H1_MechINS−Fi NbMontage_GG2−3_EN

Installation steps

5 mm

SSP94NF004

How to proceed for standard mounting:
1. Prepare M5 threaded holes on the mounting plate, for instance according to the

mounting grid.
– Always use all mounting points specified.

2. Tightly screw together filter and mounting base.

Screws

Tightening torque

E94AZxS0044

2 x M5x20

3.4 Nm (30 lb−in)

E94AZxS0104

E94AZxS0294

2 x M5x25

3. Under limited space conditions, filter and mounting base can be connected

electrically. (

^ 50)

4. Screw the filter onto the mounting plate.

– Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
– If further devices are to be mounted directly adjacent on the right−hand side of the

filter, do not tighten the screws fully before all devices are mounted and aligned.

– Tightening torque: 3.4 Nm (30 lb−in).