Connection data, 6electrical installation – Lenze E94AZRS0294 User Manual
Page 52
Advertising
![background image](/manuals/565798/52/background.png)
Electrical installation
Connection data
EDK94AZRS DE/EN/FR/ES/IT 6.0
52
l
H1_E_INST−Fi Verdraht
Connection data
Mains
Terminal X301
Labelling
Description
L1
L2
L3
Connection of the mains phases L1, L2, L3
+
Connection for the supply−side PE conductor with M5 ring
cable lug
SSP94FF008
Terminal data
Max. conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
E94AZRS0044
2.5
14
0.5 ... 0.6
4.42 ... 5.31
PH1
E94AZRS0104
4
12
E94AZRS0294
10
8
1.2 ... 1.5
10.6 ... 13.3
PE connection data
Æ
Starting torque
!
[mm]
[Nm]
[lb−in]
E94AZRS0044
M5
3.0
26.5
SW 8
E94AZRS0104
E94AZRS0294