Mounting steps

SSP94FF603

Proceed as follows for the installation:
1. Drill M6 threaded holes in the mounting plate and attach screws and

washers.

–

Four M6 screw and washer assemblies or M6 hexagon socket screws
(property class 8.8) with washers.

–

Attach the screws loosely first.

2. Attach the filter to the prepared mounting plate.

–

Tighten the screws hand−tight.

3. Attach screws and washers to the threaded holes for fastening the

standard device on the filter.

–

Four screw and washer assemblies or hexagon socket screws
M6 x 20 mm with washers.

–

Attach the screws loosely first.

4. Attach the standard device to the filter and tighten the screws fully.

–

Observe the notes given in the documentation for the standard device.

–

Tightening torque: 8 Nm (70.8 lb−in)

5. If necessary, pre−assemble further units.
6. Align all units.
7. Screw all units tightly to the mounting plate.

–

Tightening torque: 10 Nm (88.5 lb−in)