Mounting steps, Mechanical installation – Lenze E94AZRS0954 User Manual

Page 40

Advertising
background image

Mechanical installation

Standard mounting
Mounting steps

5

l

40

EDK94AZRS6 DE/EN/FR/ES/IT 7.0

5.2.2

Mounting steps

SSP94FF603

Proceed as follows for the installation:
1. Drill M6 threaded holes in the mounting plate and attach screws and

washers.

Four M6 screw and washer assemblies or M6 hexagon socket screws
(property class 8.8) with washers.

Attach the screws loosely first.

2. Attach the filter to the prepared mounting plate.

Tighten the screws hand−tight.

3. Attach screws and washers to the threaded holes for fastening the

standard device on the filter.

Four screw and washer assemblies or hexagon socket screws
M6 x 20 mm with washers.

Attach the screws loosely first.

4. Attach the standard device to the filter and tighten the screws fully.

Observe the notes given in the documentation for the standard device.

Tightening torque: 8 Nm (70.8 lb−in)

5. If necessary, pre−assemble further units.
6. Align all units.
7. Screw all units tightly to the mounting plate.

Tightening torque: 10 Nm (88.5 lb−in)