Electrical installation

Important notes

6

l

43

EDK94AZRS6 DE/EN/FR/ES/IT 7.0

6

Electrical installation

6.1

Important notes

ƒ

Installation must

always be in accordance with the operating conditions specified in the
Technical data (

34).

be carried out to EN 60204−1.

ƒ

Please observe the following when selecting the cable type:

The cables used must comply with the approvals required for the
application (e. g. VDE, UL etc.).

Fuses and cable cross−sections must be dimensioned in accordance with
the specifications in the documentation for the basic device.

{

Danger!

Dangerous electrical voltage

All power terminals remain live for up to three minutes after mains
disconnection.

Possible consequences:

ƒ

Death or severe injuries when touching the power terminals.

Protective measures:

ƒ

Switch off the power supply and wait for at least three minutes
before working on the power terminals.

ƒ

Make sure that all power terminals are deenergised.