Lenze ¯ MA 12.0015 ¯ 1.0

Remedy

Possible cause

Fault
Irregular running

Insufficient shielding of
motor or resolver cable

Checking shielding and earth connection

Drive controller gain too
large

Adjust the gains of the controllers (see Drive
controller operating instructions)

Vibrations

Insufficiently balanced
coupling elements or
machine

Rebalance

Inadequate alignment of
drive train

Realign machine unit, check foundation if
necessary

Loose fixing screws

Check and tighten screw connections

Running noises

Foreign particles inside the
motor

Repair by manufacturer if necessary

Bearing damage