Mechanical installation – Lenze E82ZBU User Manual
Page 8
Mechanical installation
EDK82ZBU DE/EN/FR 4.0
8
l
H1_MechINS−inst_mech_en
2
Mechanical installation
The switch/potentiometer unit can be mounted to the heatsink of a motec or a wall.
Mounting to the heatsink of a motec
0
1. Mount the mounting plate with 2 screws M4 x 20 and 2 spring steel sheets
0 to the
heat sink.
2. Wire the switch/potentiometer unit
– to the standard−I/O
– to the application−I/O
^ 10
3. Assemble the motec (
^ Mounting Instructions for motec
)
4. Mount the switch/potentiometer unit with 4 screws M4 x 30
1to the mounting
plate.
Wall mounting
1. Mount the mounting plate to the wall using appropriate screws.
2. Mount the switch/potentiometer unit with 4 screws M4 x 30 to the mounting plate.
3. Wire the switch/potentiometer unit
– to the Standard−I/O
^ 9
– to the Application−I/O
^ 10
4. Assemble the motec (
^ Mounting Instructions for motec
)