2 rated data, Rated data, Technical data – Lenze E82ZN User Manual

Page 30

Advertising
background image

Technical data

Rated data

4

l

30

EDK82ZN903 DE/EN/FR 5.1

Mounting conditions

Mounting location

In the control cabinet

Mounting position

between mounting plate and basic device

Mounting position

Vertical, connections on top

Free spaces

at the top

> 150 mm

at the bottom

> 100 mm

to the sides

> 50 mm

4.2

Rated data

Basis of the data

Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 ... 65

3/PE AC

480

432 − 0 % ... 528 + 0 %

45 ... 65

3/PE AC

500

450 − 0 % ... 550 + 0 %

45 ... 65

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C



max. +55 °C



E82ZZ15334B...

400/480/500

50/60

43/43/43

26.8/26.8/26.8

3

E82ZN22334B...

400/480/500

50/60

42/42/42

26.3/26.3/26.3

3

E82ZN30334B...

400/480/500

50/60

55/55/55

34.3/34.3/34.3

3

E82ZN45334B...

400/480/500

50/60

80/80/80

50.0/50.0/50.0

3

E82ZN55334B...

400/480/500

50/60

100/100/100

62.5/62.5/62.5

3

E82ZN75334B...

400/480/500

50/60

135/135/135

84.3/84.3/84.3

3

E82ZN90334B...

400/480/500

50/60

165/165/165

103/103/103

3

 Temperature in the control cabinet

Power loss

Inductance

Voltage drop

P

loss

[W]

L [mH]

DU [V]

E82ZZ15334B...

50

E82ZN22334B...

100

0.70

9

E82ZN30334B...

200

0.47

10

E82ZN45334B...

200

0.35

10

E82ZN55334B...

400

0.30

10

E82ZN75334B...

200

0.15

7

E82ZN90334B...

350

0.15

9

Advertising