Function block library LenzeElectricalShaft.lib

Special functions

2.1.1

Digital frequency ramp generator (L_DFRFG)

2−1

L

LenzeElectricalShaft.lib EN 1.2

2

Function blocks

2.1

Special functions

2.1.1

Digital frequency ramp generator (L_DFRFG)

This FB synchronizes the drive (motor shaft) to a digital frequency (phase−angle input). The drive then
runs in phase−synchronism with the digital frequency.

L _ D F R F G

C T R L

S

Q

R

d w T i f F o r Q s p b y S p e e d D i r e c t i o n

d w T i r d n O f f s e t

b y F u n c t i o n w S y n W i n d o w

n M a x S p e e d

d w T h r e s h o l d F o l l o w i n g E r r o r

b S y n c _ b

n O u t _ v

b F a i l _ b

n I n _ v

b Q S P _ b

b S t o p _ b

b R e s e t _ b

d n S e t T P L a s t S c a n _ p

b S e t T P R e c e i v e d _ b

T P / M P -

C t r l

Abb. 2−1

Digital frequency ramp generator (L_DFRFG)

VariableName

DataType

SignalType

VariableType

Note

bSetTPReceived_b

Bool

binary

VAR_INPUT

Zero−pulse or TP (TouchProbe) received

dnSetTPLastScan_p

Double Integer

position

VAR_INPUT

Difference increments between TP and start of the
task

nIn_v

Integer

velocity

VAR_INPUT

Speed/phase−angle setpoint (16384

º 15000 rpm)

bQSP_b

Bool

binary

VAR_INPUT

TRUE = Quickstop

bStop_b

Bool

binary

VAR_INPUT

TRUE = save setpoint

bReset_b

Bool

binary

VAR_INPUT

TRUE = reset

bSync_b

Bool

binary

VAR_OUTPUT

TRUE = drive runs synchronously

nOut_v

Integer

velocity

VAR_OUTPUT

Speed/Phase setpoint

bFail_b

Bool

binary

VAR_OUTPUT

TRUE = exceeded phase−angle difference

dwTir

Double Word

−

VAR CONSTANT RETAIN

Acceleration time

nMaxSpeed

Integer

−

VAR CONSTANT RETAIN

max. rate of catching up

dwTifForQSP

Double Word

−

VAR CONSTANT RETAIN

Deceleration time for QSP (Quickstop)

dwThreshold
FollowingError

Double Integer

−

VAR CONSTANT RETAIN

Second contouring error
(65335

º 1 turn)

wSynWindow

Word

−

VAR CONSTANT RETAIN

Synchronization window

dnOffset

Double Integer

−

VAR CONSTANT RETAIN

Offset related to the digital frequency input
(65335

º 1 turn)

byFunction

Byte

−

VAR CONSTANT RETAIN

Start with/without TP

bySpeedDirection

Byte

−

VAR CONSTANT RETAIN

Input of the direction of rotation