2 l_dfset, 3 l_gearcomp, L_dfset – Lenze DDS Global Drive PLC Developer Studio User Manual

Page 42: L_gearcomp, Function block library lenzeelectricalshaft.lib

Advertising
background image

Function block library LenzeElectricalShaft.lib

Appendix

3.1.2

L_DFSET

3−2

L

LenzeElectricalShaft.lib EN 1.2

3.1.2

L_DFSET

FB description:

(

^ 2−8)

Code

LCD

Possible settings

IMPORTANT

Lenze

Choice

C0033 nGearDenominator

1

1 {1}

32767 Gearing factor (denominator) of L_DFSET1

C0252 dnPosOffset

0

−245760000 {1

inc} 245760000 Phase−angle offset of L_DFSET1

·

Fixed phase offset for digital frequency
configuration

– 1 turn = 65536 inc

C0253 nSpeedDependPosOffset

0

−32767 {1

inc} 32767 Phase−angle trimming of L_DFSET1

·

Speed−dependent phase trimming

·

Depending on C0025. The change of
C0025 resets C0253 to the Lenze default
setting.

·

1 turn = 65536 inc

·

C0253 is reached at 15000 rpm

C0255 dwFollowingErrWin

327680

10 {1

inc}

1800000000 Contouring−error limit for error P03" of

L_DFSET1

·

1 turn = 65536 inc

·

Contouring error > C0025 triggers fault

P03"

C0529 nAngelOffsetMult

1

−20000 {1} 20000 Offset multiplier of L_DFSET1

C0530 bWithoutGearfactor

1

0

with g factor

1

no g factor

Evaluation of the setpoint integrator of
L_DFSET1 (with/without gearing factor)

C0531 wAct0PulseDiv

0

0 {1}

16384 Actual zero−pulse divider of L_DFSET1

C0533 wGainDenominator

1

1 {1}

32767 Gain factor (denominator) of L_DFSET1

C0534 by0PulseFunc

0

0 Inactive
1 Continuous
2 Cont.

switch

10

Once, fast way

11 Once,

CW

12 Once,

CCW

13 Once,

2*0−puls

Zero−pulse function of L_DFSET1

C0535 wSet0PulseDiv

0

0 {1}

16384 Set zero−pulse divider of L_DFSET1

3.1.3

L_GEARCOMP

FB description:

(

^ 2−16)

Code

LCD

Possible settings

IMPORTANT

Lenze

Choice

C1260 nOffset

0

−16383 {1} 16383 Offset of L_GEARCOMP

C1261 nNumerator

1

−32767 {1} 32767 Numerator of L_GEARCOMP

C1262 nDenominator

1

1 {1}

32767 Denominator of L_GEARCOMP

Advertising