Function block library lenzeelectricalshaft.lib, 1 profile generator, Stop – Lenze DDS Global Drive PLC Developer Studio User Manual

Page 12

Advertising
background image

Function block library LenzeElectricalShaft.lib

Special functions

2.1.1

Digital frequency ramp generator (L_DFRFG)

2−2

L

LenzeElectricalShaft.lib EN 1.2

Parameter codes of the instances

VariableName

L_DFRFG1

SettingRange

Lenze

dwTir

C0751

0.001 ... 999.900 s

1.000

nMaxSpeed

C0752

1 ... 16000 rpm

3000

dwTifForQSP

C0753

0.000 ... 999.900 s

0.000

dwThreshold
FollowingError

C0754

10 ... 2000000000 incr.

2000000000

wSynWindow

C0755

0 ... 65535 incr.

100

dnOffset

C0756

−2147483647 ... 2147483647 incr.

0

byFunction

C0757

0, 1

0

bySpeedDirection

C0766

1 ... 3

1

Range of functions

·

Profile generator

·

Quickstop

·

Ramp generator stop

·

RESET

·

Detect phase difference

·

Set offset

·

Connection of the function block

Note!

This FB operates with remainder handling.

2.1.1.1

Profile generator

t

n I n _ v

n M a x S p e e d

d w T i r

d w T i r

w S y n W i n d o w

b S y n c _ b

t

n O u t _ v

Abb. 2−2

Diagram of the synchronization of L_DFRFG

The profile generator generates ramps which lead the setpoint phase to its target.

·

Use dwTir to set the ramp−up and ramp−down times (1000

º 1 s).

·

Use nMaxSpeed to set the maximum speed (17476

º 16000 rpm).

·

If the distance and the speed reach their setpoints, the output switches bSync_b = TRUE. At
the same time, the FB switches the profile generator inactive and nIn_v is output to nOut_v.

·

Use wSynWindow to set the changeover point for bSync_b (1

º 1 incr.).

Stop!

Do not operate the drive at the torque limit with this function

max

, I

max

.

Advertising