Function block library LenzeElectricalShaft.lib

Special functions

2.1.4

Homing function (L_REF)

2−20

L

LenzeElectricalShaft.lib EN 1.2

2.1.4.2

Homing Modes

The home position is defined by:

·

the homing mode byHomingMode

·

the reference point offset dnRefOffset

Note!

When using feedback from a resolver,the zero position is used, not the zero−pulse (depending on the
resolver attached to the motor), and, for homing with the TouchProbe, the TouchProbe phase−angle.

Homing with a reference switch to zero pulse (MP)/zero position or TouchProbe (TP)
via the TP/MP−CTRL interface

The reference point is situated after the TRUE−FALSE edge of the reference switch bMark_b , at the
next zero−pulse/zero position, or TP plus the reference mark offset:

·

It depends on the setting of the system block that provides the actual speed, whether homing
is made to zero−pulse/zero position or TouchProbe:
– With SB MCTRL_MotorControl the setting is made through C0911 (0=MP, 1=TP via E4).
– With SB DF_IN_DigitalFrequency the setting is made through C0428 (0=MP, 1=TP via E5).
– For further information, see the description for SB MCTRL_MotorControl and SB

DF_IN_DigitalFrequency in the Manual 9300 Servo PLC".

·

Mode 0 ( byHomingMode = 0):
– Move to the home position in CW rotation.
– Home position offset dnRefOffse is entered as positive.

R

S

T P / n N A c t _ v

b M a r k _ b

Q

d n R e f O f f s e t

T

Abb. 2−13

Homing with zero−pulse/zero position or TouchProbe; moving to the reference mark in the cw direction of rotation

 Distance
‚ Start position
ƒ Direction