background image

2.9

DIGITAL_IO (node number 1)

Drive PLC

System blocks

2−24

L

DrivePLC DE 6.0

2.9

DIGITAL_IO (node number 1)

2.9.1

Inputs_DIGITAL (digital inputs)

This SB reads the signals at terminals I1 ... I8 and conditions them.

I1

I2

DIGIN_bIn1_b

Inputs_DIGITAL

C0443

I3

I4

I5

I6

I7

I8

DIGIN_bIn2_b

DIGIN_bIn3_b

DIGIN_bIn4_b

DIGIN_bIn5_b

DIGIN_bIn6_b

DIGIN_bIn7_b

DIGIN_bIn8_b

Fig. 2−14

Inputs_DIGITAL

System variables

Variable

Data type

Signal type

Address

Display

code

Display

format

Notes

DIGIN_bIn1_b

Bool

binary

%IX1.0.0

C0443 − bit1

bin

Digital inputs I1 ... I8

DIGIN_bIn2_b

%IX1.0.1

C0443 − bit2

DIGIN_bIn3_b

%IX1.0.2

C0443 − bit3

DIGIN_bIn4_b

%IX1.0.3

C0443 − bit4

DIGIN_bIn5_b

%IX1.0.4

C0443 − bit5

DIGIN_bIn6_b

%IX1.0.5

C0443 − bit6

DIGIN_bIn7_b

%IX1.0.6

C0443 − bit7

DIGIN_bIn8_b

%IX1.0.7

C0443 − bit8

Electrical data of the input terminals

Terminal

Use

Data

I1

freely assignable

LOW level:
HIGH level:
Input current:

0 ... +4 V
+13 ... +30 V
8 mA per input (at 24 V)

I2
I3
I4
I5
I6
I7
I8

Tip!

You can use I2 ... I4 as real interrupt inputs. The references to the hardware interrupt inputs are in the
task configuration. Response time of the interrupt task: < 250

m

s.

More detailed information about Drive PLC terminal strips/control connections can be found in the
corresponding Mounting Instructions!