Digital_io (node number 1), Inputs_digital (digital inputs), Drive plc – Lenze Global Drive PLC Developer Studio User Manual
Page 38: 9 digital_io (node number 1), System blocks, 1 inputs_digital (digital inputs)

2.9
DIGITAL_IO (node number 1)
Drive PLC
System blocks
2−24
L
DrivePLC DE 6.0
2.9
DIGITAL_IO (node number 1)
2.9.1
Inputs_DIGITAL (digital inputs)
This SB reads the signals at terminals I1 ... I8 and conditions them.
I1
I2
DIGIN_bIn1_b
Inputs_DIGITAL
C0443
I3
I4
I5
I6
I7
I8
DIGIN_bIn2_b
DIGIN_bIn3_b
DIGIN_bIn4_b
DIGIN_bIn5_b
DIGIN_bIn6_b
DIGIN_bIn7_b
DIGIN_bIn8_b
Fig. 2−14
Inputs_DIGITAL
System variables
Variable
Data type
Signal type
Address
Display
code
Display
format
Notes
DIGIN_bIn1_b
Bool
binary
%IX1.0.0
C0443 − bit1
bin
Digital inputs I1 ... I8
DIGIN_bIn2_b
%IX1.0.1
C0443 − bit2
DIGIN_bIn3_b
%IX1.0.2
C0443 − bit3
DIGIN_bIn4_b
%IX1.0.3
C0443 − bit4
DIGIN_bIn5_b
%IX1.0.4
C0443 − bit5
DIGIN_bIn6_b
%IX1.0.5
C0443 − bit6
DIGIN_bIn7_b
%IX1.0.6
C0443 − bit7
DIGIN_bIn8_b
%IX1.0.7
C0443 − bit8
Electrical data of the input terminals
Terminal
Use
Data
I1
freely assignable
LOW level:
HIGH level:
Input current:
0 ... +4 V
+13 ... +30 V
8 mA per input (at 24 V)
I2
I3
I4
I5
I6
I7
I8
Tip!
You can use I2 ... I4 as real interrupt inputs. The references to the hardware interrupt inputs are in the
task configuration. Response time of the interrupt task: < 250
m
s.
More detailed information about Drive PLC terminal strips/control connections can be found in the
corresponding Mounting Instructions!