Drive PLC
System blocks
2.9
DIGITAL_IO (node number 1)
2−25
L
DrivePLC DE 6.0
2.9.2
Outputs_DIGITAL (digital outputs)
This SB conditions digital signals and outputs them at terminals O1 ... O4.
O1
O2
DIGOUT_bOut1_b
Outputs_DIGITAL
O3
O4
DIGOUT_bOut2_b
DIGOUT_bOut3_b
DIGOUT_bOut4_b
C0444
Fig. 2−15
Outputs_DIGITAL
System variables
Variable
Data type
Signal type
Address
Display
code
Display
format
Notes
DIGOUT_bOut1_b
Bool
binary
%QX1.0.0
C0444 − Bit1
bin
Digital outputs O1 ... O4
DIGOUT_bOut2_b
%QX1.0.1
C0444 − Bit2
DIGOUT_bOut3_b
%QX1.0.2
C0444 − Bit3
DIGOUT_bOut4_b
%QX1.0.3
C0444 − Bit4
Electrical data of the output terminals
Terminal
Use
Data
O1
freely assignable
LOW level:
HIGH level:
Output current:
0 ... +4 V
+13 ... +30 V
max. 1 A per output
O2
O3
O4
Tip!
If the user program has not been started, all outputs are defined as "LOW" after switch−on.
More detailed information about Drive PLC terminal strips/control connections can be found in the
corresponding Mounting Instructions!