Analog4_io_eb3 (node number 14), Drive plc, System blocks − extension board 3 – Lenze Global Drive PLC Developer Studio User Manual
Page 70
Advertising

7.1
ANALOG4_IO_EB3 (node number 14)
Drive PLC
System blocks − Extension Board 3
7−2
L
DrivePLC DE 6.0
7.1
ANALOG4_IO_EB3 (node number 14)
7.1.1
Inputs_ANALOG4 (analog input 4 of extension board 3)
This SB is the interface for analog signals via terminal AI4, A
^ of the extension board 3.
AI4
A
AIN4_nIn_a
Inputs_ANALOG4
Fig. 7−1
Inputs_ANALOG4
System variables
Variable
Data type
Signal type
Address
Display
code
Display
format
Notes
AIN4_nIn_a
Integer
analog
%IW14.0
−
dec [%]
Analog input 4
Terminal assignment
Terminal X2
Use
Data
AI4
Analog input 4
Level:
Resolution:
Internal resistance:
Normalisation:
−10 V ... +10 V
10 bits + sign
100 k
W
±10 V º ±16384 º ±100 %
A
^
Internal ground, GND
−
Advertising