Technical data

General data and operating conditions

4

l

45

EDKRBS470R DE/EN/FR 8.0

4

Technical data

4.1

General data and operating conditions

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

Approval

UR

UL508

Industrial Control Equipment, Underwriter
Laboratories (File−No. E208678) for USA and Canada

Protection of persons and equipment

Enclosure

EN 60529

IP65

NEMA 250

Protection against contact to type 4

Thermal contact

Design

NC contact, 230 °C

Switching capacity

250 V AC / 0.5 A

Environmental conditions

Climate

Storage

IEC/EN 60721−3−1

1K3 (−25 ... +60 °C)

Transport

IEC/EN 60721−3−2

2K3 (−25 ... +70 °C)

Operation

IEC/EN 60721−3−3

3K3 (−10 ... +55 °C)
Current derating from +45 ... +55 °C: 2.5 %/°C

Site altitude

0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating 5 %/1000 m

Vibration resistance

(9.81 m/s

2

= 1 g)

EN 50178,
IEC 61800−5−1,
Germanischer
Loyd, general
conditions

Acceleration resistant up to 1 g

Advertising