Technical data

General data and operating conditions

4

l

46

EDKRBS470R DE/EN/FR 8.0

Mounting conditions

Mounting location

l

The mounting location must comply with the
device features mentioned in the chapter "General
data".

l

Flammable materials or substances may not be
placed in the vicinity of the brake resistor.

l

The heat generated by the brake resistor must be
dissipated freely.

Mounting position

Standard

Vertically suspended with connections at the bottom.

Variant

Horizontally standing with fixing bracket at the
bottom. The permanent power P

d

is to be reduced by

20 %!

Free spaces

Standard

at the top > 200 mm, to the sides > 25 mm, at the
bottom > 100 mm

Variant

at the top > 200 mm, to the sides > 45 mm