Technical data

Rated data

4

l

47

EDKRBS470R DE/EN/FR 8.0

4.2

Rated data

Electrical data

R

B

P

d

Q

B

U

max

[

W]

[W]

[kWs]

[V

DC

]

ERBS020R03K2

20

3200

480.0

800

ERBS039R01K6

39

1640

246.0

ERBS082R780W

82

780

117.0

ERBS100R625W

100

625

94.0

ERBS180R350W

180

350

53.0

ERBS240R300W

240

300

45.0

ERBS470R150W

470

150

22.5

R

B

Resistance

P

d

Permanent power

Q

B

Heat quantity

U

max

Max. operating voltage

Temperatures

T

nom

T

TK

T

max

[°C]

On the surface

250

400

1000

On the clearance
edge

*)

120

200

300

T

nom

Maximum temperature for rated data

T

TK

Temperature at which the thermal contact is activated

T

max

Maximum temperature in the case of improper use

*)

Measured for air as the ambient medium (small coefficient of thermal
conductivity); if materials which heat up are located at the clearance edge
(greater coefficient of thermal conductivity), the temperature continues to
rise.