9

4.3.

Brake chopper connection

4.3.1. Brake chopper 6032G with frequency inverters 8201-8204

L1

U

V

W

+UG

-UG

M

3~

PE

Filter

RB1RB2 +UG -UG

K1

K1

Brake
resistor
RB

L1

N

PE

8201E to 8204E

6032G

Motor choke /
motor voltage
filter

RB

Brake chopper

N

K1

Cable protection

Mains choke

The cross section of the PE
connection must be at least as
large as the cross section of the
power connection.

Mains filter

Operation of 8204E only with
assigned mains choke

Mains contactor

PE and screen connections
at inverter

Caution! All power terminals remain
live up to 3 minutes after mains
disconnection

Screened cables and mains filter
are required for radio interference
suppression to EN 55011.
Level A or B
Terminal bus in control cabinet

For group drives a motor protection
relay is necessary.
PTC thermistors or thermostats
are recommended for temperature
monitoring

Motor interconnection:

at 230/400V