Features
The brake choppers 6032, 6033 und 6034 are additional
components for frequency inverters with DC bus.
In generator mode, e.g. during deceleration of the drive, the
machine feeds back energy into the DC bus of the controller. If, as
a result, the DC bus voltage exceeds the maximum permissible
value, pulse inhibit will be set and "Overvoltage" will be displayed.
As soon as the voltage falls below this maximum permissible value,
the controller will be enabled again.
•
Enclosure IP00 for cabinet assembly
•
Assembly on DIN rails, alternatively assembly on module
resistors
•
Dissipation of brake energy in form of heat
•
Very short brake times possible
•
If not defined, the controller will not set pulse inhibit during
braking
1.1.
Scope of delivery
•
Brake chopper
•
Snap-on assembly kit for DIN rails
•
Operating Instructions
2.
Technical data
Brake chopper
6032_G
6033_G
6034_G
Order no.
33.6032_G
33.6033_G
33.6034_G
Article no.
340 917
340 918
366 190
Supply voltage
Switching threshold
Permanent brake power
Peak brake power
Max. brake enery
Smallest brake resistor
270-380VDC
375VDC
1.5kW
3.0kW
60kWs
47
Ω
470-660VDC
650VDC
2.6kW
5.1kW
100kWs
82
Ω
520-730VDC
725VDC
2.6kW
5.1kW
100kWs
100
Ω
Temperature range
0 - 45°C
Storage temperature
-20°C to +70°C
Humidity
Humidity class G to DIN 40040
max. 85%, no condensation
The following brake chopper types are available:
•
6032G:
For frequency inverters with single-phase mains connection
(V
rated
230V
∼
) e.g. 8201-8204.
•
6033G:
For frequency inverters with three-phase mains connection
(V
rated
400V
∼
) e.g. B. 8211-8216.
•
6034G:
For frequency inverters with three-phase mains connection
(V
rated
460V
∼
for application in e.g. USA) e.g. 8211-8215.