Lenze 6034 Brake chopper User Manual

Page 12

Advertising
background image

10

4.3.2. Brake choppers 6033G and 6034G with frequency inverters

8211-8216

L1

U

V

W

+UG

-UG

M

3~

PE

Filter

RB1 RB2 +UG -UG

K1

K1

Brake

resistor

RB

Caution! All power terminals remain

live up to 3 minutes after mains

disconnection

For group drives a motor protection

relay is necessary.

PTC thermistors or thermostats are

recommended for temperature

monitoring

Cable protection fuse

Mains choke

L3

N

PE

8211E to 8218E

6033G

6034G

Motor choke /

motor voltage

filter

The cross section of the PE has to be

at least as large as the cross section

of the power connection

RB

Mains filter

Screened cables and mains filters

are required for radio interference

suppression to EN 55011.

Operation of 8214E and 8218E only

with assigned mains choke

Brake chopper

L1

L2

L2

L3

K1 K1

K1

Mains contactor

PE and screen connection at

inverter

Terminal bus in control cabinet

Motor interconnection: Y at 230/400V

at 400/690V

ϑ

Off

On

Advertising