Installation

8250BA0903

4-1

4 Installation

4.1 Mechanical installation

4.1.1

Important notes

• Use the brake units only as built-in devices!
• Observe free space!

- Allow a free space of 100 mm at the top and at the

bottom.

• Ensure unimpeded ventilation of cooling air and outlet of

exhaust air.

• If the cooling air contains pollutants (dust, fluff, grease,

aggressive gases ), which may impair the function of the
brake units:
- Take suitable preventive measures , e.g. separate air

duct, installation of filters, regular cleaning, etc.

• Do not exceed the permissible range of the operating

ambient temperature (see chapter 3.2).

• If the brake units are permanently subjected to vibration or

shaking:
- Check whether shock absorbers are necessary.

Danger!

Operation with 8253 brake chopper and external brake resistor:

• In the event of failures, brake resistors can become very

hot, they can even burn. E.g. when the following occurs:
- mains overvoltage,
- application-specific overload,
- internal fault.

• Brake resistors must therefore be installed such that the

very high temperatures possible cannot cause any
damage.

Show/Hide Bookmarks