6 troubleshooting and fault elimination, Troubleshooting and fault elimination – Lenze 8250 series Brake unit User Manual
Page 32
Advertising
Troubleshooting and fault elimination
8250BA0903
6-1
6 Troubleshooting and fault elimination
Fault
Cause
Remedy
Green LED is not illuminated
No voltage at terminals +U
G
, -U
G
• Switch on the mains
• Connect the brake unit to the
terminals +U
G
, -U
G
of the
controller
Controller sets pulse inhibit during
braking and indicates overvoltage
• Yellow LED is not illuminated
The brake unit is not connected to
the terminals +U
G
, -U
G
of the
controller
Connect the brake unit to the
terminals +U
G
, -U
G
of the controller
• Yellow LED is illuminated
Brake resistor is not connected
Connect brake resistor
Brake resistance too high
Use lower-value brake resistor
Show/Hide Bookmarks