Preconditions – Lenze ApplicationTemplate PackML (PLC Designer R3-x) User Manual
Page 12

Preconditions
Setting up communication to the Controller
12
Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
• Enter the desired IP address of the controller.
[3-2]
Example: Enter the IP address of the Controller, standard setting: 192.168.5.99
3. Click OK to add the controller as gateway.
4. By double-clicking the desired channel (or clicking the Set active path button), set the
channel selected in the device view below the gateway as active path to the controller.
• Thus, all communication actions directly refer to this channel.
• The currently active path is represented in bold in the list and "(active)" is attached:
5. A device represented in italics is set as active path but has not been found during the last
network scan.
Note!
During initial commissioning, observe the predefined IP address: 192.168.5.99
Further information can be found in the following documentation:
Controller - Parameter setting & configuration