Working with the ApplicationTemplate PackML
Mapping the actual machine structure: Add devices
40
Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3. Setting the cycle time
• The value for the EtherCAT master cycle time has to be defined according to the cycle
time of the quickest task.
• The
icon in front of the respective device indicates the successful
EtherCAT communication.
Note: The EtherCAT cycle time is to be set to the quickest task cycle time set. In this
ApplicationTemplate PackML, the quickest task cycle time is set to 2 ms, therefore 2000 μs
have to be set here.
• If the "Distributed Clocks" option is activated for all controllers and communication is
successful, the EtherCAT Master provides the "DC In-Sync" message: