Machine module ( 51), Working with the applicationtemplate packml – Lenze ApplicationTemplate PackML (PLC Designer R3-x) User Manual
Page 51

Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014
51
Working with the ApplicationTemplate PackML
Integrating I/O modules of the I/O system 1000 with a machine module
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.10
Integrating I/O modules of the I/O system 1000 with a machine module
This chapter describes in which way the modules of an I/O system connected via CAN can be
accessed from a machine module.
Example: Access three digital inputs/outputs and one analog input /O system 1000 from the
MM_Module1 machine module.
How to proceed:
1. Right-click I_O_module_coupler
• Execute the Start Search menu command
The following dialog window shows all I/O modules identified.
• Click the Copy all device to project button to insert all devices found into the project.