5 DI-1000

COMMAND

S

UMMARY

The commands for the DI-1000 can all be entered without parameters to have the DI-1000 report
the value of the appropriate parameters in memory. For example, entering UNIT KG← sets the DI-
1000 units to KG. Now entering UNIT← gets the DI-1000 to respond with the currently set units, i.e.
KG.

5.1.1

UNIT

Function:

Set (returns) currently selected units

Summary:

Sets or returns one of the 3 unit types: LB (pounds), Kg (kilograms) or N
(Newtons) both for internal and output usage..

Example:

UNIT LB ← (to set units TO POUNDS)

UNIT ← (to display currently set units)

5.1.2

Function:

Sets (returns) the load capacity of the attached load-cell

Summary:

Sets or returns the total load capacity of the load-cell as a floating point number.
Should be entered in the currently selected value of UNIT.

Example:

UNIT KG ← (example sets units to KILOGRAMS

LC 500 ← (sets total load capacity to 500 Kg)

LC

← displays currently set load capacity

5.1.3

ID 

Function:

Sets (Returns) a unique identification string for this device

Summary:

Sets or returns a unique identification string for this device. The total string
should not exceed 12 characters. The string value is retained between power
cycles.

Example:

ID Sensor_12

(Note that we typically enter the unit serial number as the ID at the factory)