Load unit: adjust the grips’ clamp force – MTS Series 322 Load Frames User Manual

Page 62

Advertising
background image

Series 322 Load Unit

62

Operation

A. Watch the speed at which the lower grip clamps and unclamps the

specimen.

B. Adjust the Rate control counterclockwise for the desired speed.

Load Unit: Adjust the Grips’ Clamp Force

The Pressure control adjusts the hydraulic pressure applied to the grips. The
Rate control adjusts the grips’ clamping speed. They must be adjusted before the
grips can be used.

The amount of hydraulic pressure applied depends on the type of grips you are
using and what you are gripping. Use your grip manual to determine the correct
hydraulic pressure before adjusting the force. Experiment with a dummy
specimen to find the best setting.

Note

The Pressure control can adjust the grip pressure up to the maximum
output pressure setting (which is initially set by MTS Systems
Corporation).

1. Ensure that both the upper grip control and lower grip control are in the

unclamp position.

2. Turn on the electrical power at the test controller.

3. Turn on low or high hydraulic pressure.

4. If needed, move the crosshead or actuator so that the dummy specimen can

be easily installed in the lower grip.

Grips are designed to operate within a range of hydraulic pressure.

Too much pressure can damage both the grips and the specimen.

Do not adjust grip pressure higher than the grip rating. See your grip manual to
determine the correct hydraulic pressure to apply to your grips before adjusting
the Pressure control.

CAUTION

Advertising