Series 322 Load Unit

Operation

63

5. Adjust the Pressure control for the desired hydraulic pressure.

6. If you exceed the desired pressure setting, adjust the Pressure control

counterclockwise 1/2 turn. If pressure setting exceeds 20 MPa (3000 psi)
cycle (clamp and unclamp) one of the grips. Return to Step 5.