0 precrack parameters – MTS Multipurpose Simulated User Manual
Page 73
Description
Parameter
30 Hz
JIC Data Frequency
Data Storage Parameters
Data Storage Parameter Values
Value to Use for Simulation
Parameter
100 count
Store Every Nth Precrack Cycle
0%
Precrack Save Percent Limit
20%
Lower Least Squares Fit Percentage
80%
Upper Least Squares Fit Percentage
Test Termination Parameters
Test Termination Parameter Values
Description
Parameter
Yes
JIC Max COD in Use
50 mm
JIC Maximum COD
Yes
JIC Max Crack Extension in Use
2.5 mm
JIC Max Crack Extension
No
JIC Maximum Crack Size in Use
0 mm
JIC Maximum Crack Size
No
JIC Max Displacement in Use
0 mm
JIC Maximum Displacement
No
JIC Maximum Load In Use
0 kN
JIC Maximum Load
5.5.2.3.0 Precrack Parameters
The following table lists the precrack parameters and their required values.
MTS TestSuite 73
5.0 Running Simulation Tests