6. modes – RKI Instruments GX-8000(PT0-098) User Manual

Page 25

Advertising
background image

4 How to Use

4-6. Modes

- 25 -

GX-8000

4-6. Modes


Details on each mode are provided as follows. (* Operations are slightly different depending on the type.)

Mode Item LCD

display Details

Detection
Mode

Concentration display

Normal state

Air Calibration
Mode

AIR CAL

Perform the zero adjustment.

Combustible
Gas
Measurement
Range Setting

HC RANGE

Used to select a combustible gas
measurement range manually.
(TYPES-A and E only)

Peak Display

PEAK

Display the maximum concentration (or
minimum concentration for oxygen)
detected during measurement from
power-on to the present.

STEL Value
Display

STEL

Display the STEL value after power-on.
(TYPES-A, B, C, and D only)

TWA Value
Display

TWA

Display the TWA value after power-on.
(TYPES-A, B, C, and D only)

Alarm Setpoint
Display
Alarm Test

ALARM-P

Display the full scale and alarm setpoint
values and check the alarm operations for
the settings displayed.

Pump
ON/OFF
Setting

PUMP OFF

Used to turn on/off the pump operations.

ID Setting

ID SELECT

Display an ID if it has been set in advance.
Also used to change or set an ID.

Display and
Setting Mode

Log Data
Display

REC.DATA

Display data recorded to the manual
memory.

Advertising