Maintenance, 1. maintenance intervals and items – RKI Instruments GX-8000(PT0-098) User Manual

Page 39

Advertising
background image

6 Maintenance

6-1. Maintenance intervals and items

- 39 -

GX-8000





6

Maintenance





This is an important instrument for the purpose of safety.
To maintain the performance of the gas monitor and improve the reliability of safety, perform a regular
maintenance.

6-1. Maintenance intervals and items


• Daily maintenance: Perform maintenance before beginning to work.

• Monthly maintenance: Perform alarm test once a month.

• Regular maintenance: Perform a maintenance once or more for every six months to maintain the

performance as a safety unit.

Maintenance item

Maintenance content

Daily

maintenance

Monthly

maintenance

Regular

maintenance

Battery Level
Check

Check that the battery level is sufficient.

{

{

{

Concentration
Display Check

Make the gas monitor draw in fresh air and check that
the concentration display value is zero (or 20.9 vol%
on the oxygen deficiency meter). When the reading is
incorrect, perform the zero adjustment (fresh air
adjustment) after ensuring that no other gases exist
around it.

{

{

{

Flow Rate Check See the flow rate indicator to check for abnormalities.

{

{

{

Filter Check

Check the dust filter for dust or clogging.

{

{

{

Alarm Test

Check the alarm lamp and buzzer for normal
operation using the alarm test function.

{

{

Span Adjustment

Perform the span adjustment by using the calibration
gas.

{

Gas Alarm Check Check the gas alarm by using the calibration gas.

{

Advertising