Beacon 200 Rig Monitor Operator’s Manual • 18

WARNING: Make all connections to the Beacon 200 Rig Monitor

before you connect the DC power source. Before you
make any wiring adjustments, always verify that all power
sources are not live.

Connecting the DC Power Source

Perform the following functions to connect the Rig Monitor to DC power.
One end of the battery cable is already factory wired to the appropriate
terminals at the Rig Monitor housing. Use the other end to connect a 12
VDC battery.

NOTE: Be sure to turn off the Beacon 200 Rig Monitor before connecting

or disconnecting it from the 12 VDC battery.

1. Turn off, unplug, or disconnect all incoming power to the Rig Monitor.

2. Open the housing door, then place the power switch in the OFF

position.

3. Connect the red battery clamp to the (+) terminal of the 12 VDC battery.

4. Connect the black battery clamp to the (-) terminal of the 12 VDC

battery.

Connecting External Alarms

Perform the following procedure to connect external alarm devices to the
Rig Monitor. The common alarm 1 terminals are factory wired and are not
available for field use.

NOTE: The alarm terminal strip includes terminals for channel alarms

and common alarms. Channel alarms are activated by one
particular channel. Common alarms are activated by either of the
two channels.The example used in this procedure describes
connecting an external alarm device to one of the channel alarm
terminals: the channel 1, alarm 1 terminals.

1. Disconnect the battery clamps from the + and - terminals of the 12 VDC

battery.

2. Open the housing door, then place the power switch in the OFF

position. Locate the alarm terminal strip (see Figure 1).

3. Install an appropriately rated cable bushing in the Rig Monitor housing.

All factory supplied conduit hubs are used in the Rig Monitor, so you will
need to drill a hole in the housing for a conduit hub and cable bushing.