Configure channel settings menu – RKI Instruments Beacon 200 Rig Monitor, LEL/H2S User Manual

Page 35

Advertising
background image

Beacon 200 Rig Monitor Operator’s Manual • 30

Configure Channel Settings
Menu

This section describes how to view and change channel parameters for the
installed gas channels.

1. Simultaneously press and hold the ESCAPE and ENTER buttons for

approximately 5 seconds to enter the Channel Control & Setup
Program. Release the buttons when the Control & Setup Program
Proceed? [YES] or [NO]
message appears on the display screen.

2. Press the UP/YES button to continue.

3. Press the UP/YES or DOWN/NO button until the 2) Configure Channel

Setting(s) message appears on the display screen, then press the
ENTER button.

4. Use the UP/YES and DOWN/NO buttons to select the channel for

which you want to set parameters, then press the ENTER button.

5. Press the UP/YES button until the parameter you want to set appears

on the display screen. The screen will display the current setting and
ask if it is OK.

Table 8 lists the parameters you can set for a channel. Table 8 also lists

the factory set value for each parameter.

NOTE: Use the ESCAPE button to go back to a previously displayed

parameter.

6. If the setting is not OK and you want to change the it, press the DOWN/

NO button. The parameter is now adjustable.

7. Use the UP/YES or DOWN/NO button to update the parameter, then

press the ENTER button to continue.

8. Repeat steps 5 through 7 to set any other channel parameters.

9. Press the UP/YES button until the following message appears on the

display screen.

C o n f i g u r a t i o n

f o r

C H A N N E L

1

h a s

n

b e e

c o m p l e t e d

e

S a v

S e t t i n g s ?

[ Y / N ]

Advertising