UHE-F / EIH-F I&O Manual

IM100205

RD: MAY 2014

RL: 06A

 Manufactured and shipped in 10 ft lengths.
 Swaged tube has approximate 4 inch (10 cm) overlap -

 Net length of first and intermediate tubes is 116 inches (295 cm)
 Last tube is 120” (305 cm) [the 4 inch swage length is exposed for vent connection]
 Total tube length is approximately 4 inches (10 cm) shorter for each multiple of 10

feet (305 cm)

 Overall length of heater includes the burner.

** Burner weight is 26 pounds (11.8 kg)

Each 10 ft (305 cm) tube/reflector section weighs 82 pounds (37.2 kg)

INPUT

BTUH (kW)

Canada: 0’ to 4500’

USA: 0’ to 2000’

NOMINAL

LENGTH

FT (m)

OVERALL HEATER

LENGTH*

FT (m)

APPROX NET

WEIGHT**

LBS (kg)

200,000 (59)

70 (21.34)

69’-10” (21.29)

600 (272)

200,000 (59)

60 (18.29)

60'-2” (18.34)

518 (235)

160,000 (47)

60 (18.29)

60'-2” (18.340

518 (235)

160,000 (47)

50 (15.24)

50’-6” (15.39)

436 (198)

130,000 (38)

50 (15.24)

50’-6” (15.39)

436 (198)

130,000 (38)

40 (12.19)

40’-10” (12.45)

354 (161)

90,000 (26)

40 (12.19)

40’-10” (12.45)

354 (161)

90,000 (26)

30 (9.14)

31'-2” (9.50)

272 (123)

60,000 (18)

30 (9.14)

31'-2” (9.50)

272 (123)

60,000 (18)

20 (6.10)

21’-6” (6.55)

190 (86)