Ultraschwank uhe infrasave ultimate eih, Burner & tube kit assembly chart models uhe, eih – Schwank ultraSchwank EIH User Manual

Page 44

Advertising
background image

44

UHE-F / EIH-F I&O Manual
IM100205
RD: MAY 2014
RL: 06A

26. BURNER & TUBE KIT ASSEMBLY CHART MODELS UHE, EIH

MODELS UHE & EIH are approved for indoor commercial / industrial non-residential applica-

tions. For outdoor, wet and harsh environment applications refer to models UHE-P / EIH-P and

UHE-S / EIH-S.

BEFORE INSTALLING: Check that you have the correct tube kit(s) for the burner input

MODELS:

ultraSchwank UHE

InfraSave Ultimate EIH

High Radiant Output Tube Heaters for Commercial / Industrial Indoor Applications

COMPLETE

60 Mbh

60 to 130

160 & 200

6 ft

None

None

None

2 ft

6 ft

None

3 ft

TK-P620-UL TK-P020-UL TK-PH20-UL TK-S020-UL TK-S220-UL TK-S620-UL TK-S010-UL TK-S310-UL

Input Btuh

Tube

Length

20'

20'

20'

20'

20'

20'

10'

10'

20'

1

30'

1+

1

30'

1+

1

40'

1+

1

40'

1+

1

50'

1+

1+

1

50'

1+

1

1

60'

1+

1+

1

50'

1+

1+

1

60'

1+

1+

1

70'

1+

2+

1

NOTE: UHE / EIH Series Burners require 120V electrical supply

Tube Kits for models UHE & EIH have an insulated double reflector.

All tube kits include tubes, insulated reflectors, tube couplers, and hangers required for installation.

Model 60,000 x 20 ft has a 6 ft turbulator installed in a tube in the Primary Tube Kit TK-P620-UL

Tube Heaters longer than 20 feet require a Primary Kit and at least one additional Secondary Tube Kit.

- Primary Tube Kits include the flanged combustion chamber tube plus one additional tube

A Secondary Tube Kit requires a Primary Tube Kit.

- Secondary Tube Kits include steel heat exchanger tubes and turbulator if required.

* TURBULATORS:

- If a turbulator is required it is factory installed in a clearly labeled tube in the Secondary Tube Kit.
- A turbulator must always be installed in the last tube at the vent end of the heater.

160,000

200,000

90,000

130,000

Weight

Turbulator*

Tube Kit Part #

60,000

TUBE KIT PART # & QUANTITY REQUIRED

PRIMARY TUBE KITS

SECONDARY TUBE KITS

20 ft Secondary Kits

10 ft Secondary Kits

COMPLETE

60 Mbh

60 to 130

160 Mbh

200 Mbh

6 ft

None

None

None

None

2 ft

6 ft

TK-P620-UL

TK-P020-UL

TK-P160-UL

TK-P200-UL

TK-S020-UL

TK-S220-UL

TK-S620-UL

Input Btuh

Tube

Length

20'

20'

20'

20'

20'

20'

20'

20'

1

30'

1+

30'

1+

40'

1+

1

40'

1+

1

50'

1+

1+

50'

Stainless Steel Combustion Tube

1+

1

60'

Stainless Steel Combustion Tube

1+

1+

1

60'

Stainless Steel Combustion Tube

1+

1+

1

70'

Stainless Steel Combustion Tube

1+

2+

160,000

60,000

200,000

90,000

130,000

Turbulator* -->

Tube Kit Part #

Order: TUBE KIT PART # & QUANTITY REQUIRED

20 ft Secondary Kits

SECONDARY TUBE

PRIMARY TUBE KITS

Advertising
This manual is related to the following products: