Heater assembly & installation – Schwank Parasol Series Post Mount 24 volt User Manual

Page 10

Advertising
background image

4BN/L6-24,4SN/L5 -24 Manual

IM100310

RD: MAR, 2010

RL: 1A - BA

10

7. HEATER ASSEMBLY & INSTALLATION

Tools Needed: (not supplied)
Adjustable Wrench or wrench set, Slip Joint Pliers, Phillips Screwdriver-Medium Blade (#2 or #3
blade), Drill and Masonry Bit for lag anchors (if mounting on concrete patio), Plumbing Seal/Tape
for Joints, Soapy Water: Spray Bottle or Paint Brush for leak testing.

NOTE: The top surface of the heater base is 3 1/2” above patio deck. Ensure the gas supply pipe
extends sufficient length above patio deck and heater base to allow installation of shut-off valve;
allow minimum 18” of 24Vac power supply wire above deck for connection to heater wiring.

4. Connect gas hose to burner (flare connection) and tighten

connection with wrenches.

1. Locate the heater base with gas supply pipe up through hole in heater

base (4.5” / 114 mm post center to gas supply hole) or adjacent to the
heater base (9” / 228 mm from post center to outside edge of base).
Feed 24Vac power supply wire up through the center post stub.

Gas Supply

Alternate fastening

2. Install heater base to patio deck using appropriate

hardware such as lag screws (qty 3 field supplied)
through the holes in the heater base
- OR -
use the supplied brackets (qty 3) as the fastening
solution (anchor to deck hardware field supplied).

3. Insert the 24 Vac power supply wire up into the heater post, and out

through the oval port. Install post over the post stub, aligning the oval
port in post with slot in post stub. Fasten post to heater base using
sheet metal screws (qty 6) provided.

5. Feed gas hose and 24V wire from burner down the post and out

through the oval port at bottom of post. Temporarily secure the
burner assembly to post with screws supplied.

HAND TIGHTEN the burner fastening screws at this time. Once
the heater is connected to the gas supply, the burner head will
need to be lifted slightly to allow leak test of the hose connection
to the burner.

Advertising