2. Loosen, but do not remove, the six hexalobular screws that secure the top air

flow plate to the drive, then slide the plate forward to lift it off the screws.
Tightening torque is noted in the illustration for reassembly.

Note: The air flow plate cannot be removed from the drive unless the AC
input wiring and bus bar extensions (if installed) are removed. However, the
plate must be removed to remove the AC input terminals below it.

3. Disconnect the DPI cable from the HIM (if present).

4. Insert a flathead screwdriver into the holes in the right side of the protective

covers on the drive, turn the latch 90° counter-clockwise, and open the
control panel to the left.

Tightening torque:
1.5 N•m (13 lb•in)

T15

Loosen
screws

Loosen
screws

Pull plate forward to lift off screws

Top View of Drive

90°

Disconnect DPI cable