Rockwell Automation 22-COMM-P PowerFlex Profibus Adapter User Manual
Page 49

Configuring the Profibus Scanner
4-11
17. The same steps for configuring Station 1 will be used for configuring
Station 2. See previous steps (starting at step 9,
Configuring the SST-PFB-SLC Profibus Scanner-Station 2 (see
).
Figure 4.19 Station 2 Network Window
Station 2 is configured as follows:
Note that Station 2 occupies 6 words.
18. Use the null modem cable that came with the scanner to connect
COM1 on the PC and the CONFIG RS232 port on the scanner.
Note: The processor needs to be in program mode before
proceeding.
19. Right-click on the scanner in the network window and select
“Connect”. Then right-click again on the scanner in the network
window and select “Load Configuration”. If a minimum cycle time
attention window pops up, click OK to continue. After the
configuration has been loaded into the scanner, “Configured
Program” will be displayed in the message window (see
).
Figure 4.20 Network Window Scanner Selection
Module
M1/M0 Offset
Ctrl/Stat & Ref Fdbk Drive 0
6
Parameter Access
8