Figure 7.1 – Rockwell Automation 22-COMM-P PowerFlex Profibus Adapter User Manual
Page 62

7-2
Using Multi-Drive Mode
Figure 7.1 Single Mode Example - With Adapter in Drive
When the adapter cannot be installed in the drive (for example, a
PowerFlex 4 or PowerFlex 4M drive) but operated in Single mode, the
adapter can be installed in a DSI External Comms Kit (
Figure 7.2 Single Mode Example - With Adapter in DSI External Comms Kit
Figure 7.3
shows that the Single operating mode provides the possibility
of connecting one additional external peripheral.
Figure 7.3 DSI Peripheral Devices for Single Operating Mode Connection
PowerFlex 40/40P/400
Drive with 22-COMM-P
PowerFlex 40/40P/400
Drive with 22-COMM-P
PowerFlex 40/40P/400
Drive with 22-COMM-P
Profibus
1 drive per node
Profibus
up to 4 drives per node
22-COMM-P
Adapter
PowerFlex 4-Class Drive
NOTE: A terminating resistor is not
required for this end of the wiring.
The resistor is built into the circuitry
of the DSI External Comms Kit.
AK-U0-RJ45-TB2P
Kit Connector with
Terminating Resistor
RS-485
PORT
MOD
NET A
NET B
AK-U0-RJ45-TB2P
Kit Connector
22-SCM-232
or
1203-USB
HIM