Install components – Rockwell Automation 20B PowerFlex 700 Drives - Frame 10 Components Replacement User Manual
Page 46

46
Rockwell Automation Publication 20B-IN026B-EN-P - July 2013
Chapter 3
Inverter Assembly Component Replacement Procedures
6. Remove the two mounting torx screws located
on the board as shown at right.
7. Use your fingers or needle-nose pliers to
squeeze the tabs of each of the nine spacers
(see previous page for their locations), and
separate the Power Interface Board from the
mounting plate.
8. Remove the Power Interface Board; return or
dispose of it properly.
Install Components
1. Install the new Power Interface Board.
Tighten board screws to 1.8 N•m (16 lb•in).
2. Reconnect all wiring as detailed in the Table on the previous page.
3. Reconnect the Main Control Board wires to TB1 and TB2 on the Power
Interface Board.
4. Tighten sheet metal screws to 3.2 N•m (28 lb•in).
5. Reconnect the ribbon cable going from the Power Interface Board (J1) to
the Main Control Board ( J2).
6. Reinstall the Main Control Board as instructed on page
.
7. Replace all safety shields and enclosure covers before applying power to the
drive.
J24
Red/Black
TB1 on DC Bus Filter Board
TB1
Green/Yellow
PE on TB11
TB2
Red
#33, #34, and #35 on TB11
Connector
Wire Color(s)
Connects To: