Rockwell Automation 20B PowerFlex 700 Drives - Frame 10 Components Replacement User Manual
Page 59

Rockwell Automation Publication 20B-IN026B-EN-P - July 2013
59
Inverter Assembly Component Replacement Procedures
Chapter 3
7. Install the Gate Interface Board:
a. Install the Gate Interface Board using the four nuts removed previously.
Torque screws to 1.6 N•m (14 lb•in).
b. Install the supplied Gate Interconnect Harness.
c. Connect wiring between the IGBT and Gate Interface Board as shown
Gate Interface Board on page 60
.
d. Connect wires to the Current Transducer.
8. Reinstall the three IGBT Snubber Capacitors in the reverse order of
Remove all IGBT Snubber components (3 sets): on page 28
.
Torque nuts to 5.6 N•m (50 lb•in).
9. Install the Current Transducer, AC Output Busbar, and Output Busbar
.
10. If you removed the Main Control Panel and Stacking Panel to replace the
lower IGBT module, replace the panels in this order:
a.
Stacking Panel (Inverter Assembly) on page 24
.
b.
Main Control Panel (Inverter Assembly) on page 22
.
11. Replace all safety shields and enclosure covers before applying power to the
drive.